■ 使用電壓:請(qǐng)使用交流電源220V(110VAC)、單相、50Hz(60 Hz)。電壓若低于(100VAC),或高于240V(120VAC)為不正常使用,易使泵損毀。
Normal Rated Voltage should be 220VAC(110VAC)~240(120VAC).Otherwise pump won’t be obtained in a good working condition.
■ 使用環(huán)境溫度:0℃~38℃,并保持通風(fēng)良好、順暢以防溫度過高。
Working environmental temperature should be within 0℃~38℃ ,with the ventilation working place to prevent temperature of pump from rising too high.
■使用前應(yīng)接妥地線,濕手不可接觸電源。
Before use it,make sure the earth line is well equipped.Do not touch the power with wet hands.
■置于室外時(shí),嚴(yán)禁雨水濺濕、陽光暴曬,并保持泵內(nèi)、外部件干爽。
If pump is installed outside the room,please keep the pump from rain and sunshine and the inside and outside of the pump should maintain dry always.
■ 泵嚴(yán)禁注油、注水、敲擊、碰摔。
Pump couldn’t bear oil.water and colision.
■ 管路進(jìn)出口總面積大于空氣泵進(jìn)出口總截面積的85%。管路彎道盡量避免成直角,以免壓力損失過大。
The general acreage of the tube should not be less than 85% of acreage of pump outlet.Try to equip the tube with smoothing curved angle.
■ 風(fēng)量減少,請(qǐng)檢查:
1) 電壓是否正常。
2) 空氣濾清器、管路、接頭是否破損、泄氣、堵塞。
3) 泵體閥門、振動(dòng)膜是否 破損、堵塞。
4) 若置放泵之處通風(fēng)不良,導(dǎo)致溫度過高、風(fēng)量減少、請(qǐng)加強(qiáng)散熱裝置。
'